Showing posts with label Steel. Show all posts
Showing posts with label Steel. Show all posts
Saturday 8 September 2018
Joint Gutter with Cantilrver Beam WF 150 at span up to 1m
WF 150 Beam as Cantilever Rafter at span up to 1m with design Gutter at the end of rafter beam can be constrct like image below :
and detail of section 13 can see below :
Friday 7 September 2018
Roof Beam with WF 200 for Span 7 up to 8m
Roof Beam with no Concrete load... using for only Roofing Load can use WF 200 Beam with Span 7m ap to 8 m. the Joint of Construction can made like image below :
Joint Roof Beam WF 200 span 7 up to 8m, make only as Roofing Load no Concrete Load
Joint of Roof Beam Others : Betwen Rafter Beam WF 200 with column WF 350 only using for Roofing with no concrete load as floor.
Detail of Joint Section 1
Detail of Joint Section 2
Detail of Section 12
Joint Roof Beam WF 200 span 7 up to 8m, make only as Roofing Load no Concrete Load
Joint of Roof Beam Others : Betwen Rafter Beam WF 200 with column WF 350 only using for Roofing with no concrete load as floor.
Detail section 14
Others Construction with Roof Beam WF 200 span 7 up to 8m,
Detail of Joint Section 1
Detail of Joint Section 2
Detail of Section 12
Saturday 16 April 2016
Column expansion HB to WF and WF to WF
For optimalization of design, sometime we needs using diferent of material size at one of column structure. the difrenent size structure for column can be used like image below
Joint column to column betwen HB 200x200 with WF 200x100
and the detail of section A ... can see image below :
Joint column to column betwen WF 350x175 with WF 200x100
and the detail of section B ... can see image below :
Joint column to column betwen HB 200x200 with WF 200x100
and the detail of section A ... can see image below :
Joint column to column betwen WF 350x175 with WF 200x100
Wednesday 23 July 2014
Rafter Beam Joint with Structure Building
Sometimes Rafter Beam does not stop at the column Rafter at the end of Rafter Construction. The Rafter stop at the Building. Because span of Rafter left and Right not simetric or others architecture design needs.
and the Detail of section 2 can see below :
and the Rafter HC 450x150x6.5x9 joint with column building HB 200x200x8x12 can see below :
Tuesday 8 April 2014
The Kind of Joint WF350 for Beam Span 6 up to 7m
Two Stories Steel Building with Steel Beam at Span 6 up 7 m can use WF 350
the kind of Joint Structure can see Image below :
Joint End Beam WF 300 with Column HB 200
Joint End Beam WF 300 with Column WF 350 Can see Image Below :
-Multi Joint WF 350 Beam with Midle Column HB 200
Detail of section 1
the kind of Joint Structure can see Image below :
Joint End Beam WF 300 with Column HB 200
-Multi Joint WF 350 Beam with Midle Column HB 200
Detail of section 1
The Kinds of Joints for WF 200 span 5 up to 6m
WF 200 can use for Roof Beam span 5 up to 6 but for floor Beam we usualy use wf 250 for more recomendation.
on Steel Construction many kinds of joint can be use for wf 200 according to design the construction need.
Here there are sample for Wf 200 for construction.
Joint wf 200 Rafter Beam to Column wf 350
detail for section 1
Joint wf 200 Rafter Beam to column wf 200
detail for section 1
Joint many WF 200 position
detail for section 4 and 5
Joint Wf200 Column with diferent Column WF
on Steel Construction many kinds of joint can be use for wf 200 according to design the construction need.
Here there are sample for Wf 200 for construction.
Joint wf 200 Rafter Beam to Column wf 350
detail for section 1
Joint wf 200 Rafter Beam to column wf 200
detail for section 1
Tuesday 18 February 2014
WF200 Cantilever Beam for Gutter and Place Billboard
lace
Monday 3 February 2014
Steel Beam with HoneyComb Span 31 m
with Span = 31 m
Using HC 450x150x6.5x 9
Coupe WF 300x150x6.6x9
Rafter Coulomb 350x175x7x11
Sample Construction disain give here with Joint Betwen Rafter Beam and Coulomb
and Basic Disain betwen Coulomb and Lateral Beam
and see this image below :
Joint Construction Rafter Beam and Rafter Coulomb
At Joint Conection betwen Beam Rafter can see here :
if Span Beam or Dintance of Rafter Coulomb needed 5m to 6m
Joint betwen Rafter Coulomb and Lateral Beam
Detail Section 14 see below :